Gold Member Since 2010
Audited Supplier
FORLONG MEDICAL CO., LTD.

Patient Monitor, ICU Monitor, ECG Monitor manufacturer / supplier in China, offering 12.1 Inch Six Parameters Patient Monitor Flpm-9000, Luxurious Hydraulic Medical Stretcher for Emergency with CE ISO FDA, Luxurious Hydraulic Rise-and-Fall Patient Stretcher Cart and so on.

(/ )

Supplier Homepage Product Patient Monitoring & Life Support Patient Monitoring Systems 12.1 Inch Six Parameters Patient Monitor Flpm-9000

12.1 Inch Six Parameters Patient Monitor Flpm-9000

FOB Price: US $500-600 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $500-600/ Piece
Get Latest Price
Port: Shanghai, China
Production Capacity: 1000 Units/Year
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: FLPM-9000
  • Type: Patient/Fetal/Maternal Monitor
  • Trademark: FORLONG
  • Origin: Jiangsu China
  • Classification: Physiological Functions of Diagnosis and Monitoring Equipment
  • Certification: CE, ISO13485
  • Transport Package: 1 Unit/Carton
Product Description

FLPM-9000 12.1inch Patient Monitor

Features

12.1" color TFT LCD screen, resolution: 800*600

5 kinds of interfaces: Standard/Big font/6-lead

ECG/Trend gragh/OxyCRG

Maximum 8-channel waveforms display, the waveform

color can be dened by user (7 colors)

96-hour storage and review of trend graphic gram and

table, 400 groups NIBP data, 1800 alarm events

Devote to life technology

ST and arrhythmia analysis, pacemaker analysis, drug

dose calculation

Anti‐debrillation design

NIBP over pressure protection

Plug‐in rechargeable battery, AC/DC available

Support wire or wireless network

 

Technical Specication

ECG

Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)

Lead Selection: I, II, III, avR, avL, avF, V

Waveform: 2 ch

Lead Mode: 3 Leads ( R, L, F or RA, LA, LL)

Lead Selection: I, II, III,

Waveform: 1 ch

Gain: 2.5mm/mV, 5.0mm/mV,

10mm/mV,20mm/mV, auto

HR and Alarm Range: Adult: 15 ~ 300 bpm

Neo/Ped: 15 ~ 350 bpm

Accuracy: ±1% or±1bpm, which is greater

Resolution: 1 bpm

Sensitivity: > 200 (uVp-p) Differential

Input Impedance: > 5 MΩ CMRR :

Monitor > 105 dB

Operation > 105 dB

Diagnosis > 85 dB Electrode

Offset Potential: ±300mV Leakage

Current: < 10 uA

Baseline Recovery: < 3 S After De.

ECG Signal Range: ±8 m V ( Vp-p )

Bandwidth:

Surgery: 1 ~ 20 Hz

Monitor: 0.5 ~ 40 Hz

Diagnostic: 0.05 ~ 130 Hz

Calibration Signal: 1 (mVp-p), Accuracy:5% ST

Segment Monitoring Range

Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting:

Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY,

TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS, PNP,

PNC,Alarm Available,Review Available

RESP

Method: Impedance Between R-F(RA-LL)

Differential Input Impedance: > 2.5 MΩ

Measuring Impedance Range: 0.3~3 Ω

Base line Impedance Range: 200~4 KΩ

Bandwidth: 0.1~2.5Hz

Resp. Rate:

Measuring and Alarm Range:

Adult: 0 ~ 120 Brpm

Neo/Ped: 0 ~ 150 Brpm

Resolution: 1 Brpm

Accuracy: ±2 Brpm

Apnea Alarm: 10 ~ 40 S

NIBP

Method: Oscillometric Mode:

Manual, Auto, STAT

Measuring Interval in Auto Mode:

1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)

Measuring Period in STAT Mode: 5 Min

Pulse Rate Range: 40 ~ 240 bpm

Alarm Type: SYS, DIA, MEAN

Measuring and Alarm Range:

Adult Mode

SYS: 40 ~ 270 mmHg

DIA: 10 ~ 215 mmHg

MEAN: 20 ~ 235 mmHg

Pediatric Mode

SYS: 40 ~ 200 mmHg

DIA: 10 ~ 150 mmHg

MEAN: 20 ~ 165 mmHg

Neonatal Mode

SYS: 40 ~ 135 mmHg

DIA: 10 ~ 100 mmHg

MEAN: 20 ~ 110 mmHg

Resolution: 1mmHg

Accuracy: Maximum Average Error ±5mmHg

Maximum Standard Deviation ±8mmHg

Overpressure Protection Adult

Mode: 297±3 mmHg

Pediatric Mode: 240±3 mmHg

Neonatal Mode: 147±3 mmHg

SpO2

Measuring Range: 0 ~ 100 %

Alarm Range: 0 ~ 100 %

Resolution: 1 %

Accuracy: 70% ~ 100% 2 %

0% ~ 69% unspecied

Actualization Interval: about 1 Sec.

Alarm Delay: 10 Sec.

Pulse Rate:

Measuring and Alarm Range: 20~300 bpm

Resolution: 1bpm

Accuracy: ±3bpm

TEMP

Channel: 2

Measuring and Alarm Range: 0 ~ 50 ºC

Resolution: 0.1 ºC

Accuracy: ±0.2 ºC

Actualization Interval: about 1 Sec.

Average Time Constant: < 10 Sec.

IBP

Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and Alarm Range:

ART: 0 ~ 300 mmHg

PA: -6 ~ 120 mmHg

CVP/RAP/LAP/ICP: -10 ~ 40 mmHg

P1 / P2: -10 ~ 300 mmHg

Press Sensor:

Sensitivity: 5 uV/V/mmHg

Impedance: 300-3000Ω

Resolution: 1 mmHg

Accuracy: ±2% or 1mmHg which is greater

Actualization Interval: about 1 secretary

Battery: Rechargeable Li-ion battery, 14.8V 2200mAh

Standard: 3/5-Lead ECG, RESP, SpO2, NIBP, PR, TEMP

Optional: Nellcor SpO2, Mainstream/Sidestream EtCO2,

1/2 channel IBP, Touch screen, Thermal Recorder,

Wall mount, Trolley, Central station

12.1 Inch Six Parameters Patient Monitor Flpm-9000


 

Send your message to this supplier
Avatar
Mr. Danny Shen
Managing Director
*From:
To: Mr. Danny Shen
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now